Part Number Hot Search : 
S1921 MBZ5226 A9668PC 314008 SMC10 ARDUINO MAX16057 S1308M
Product Description
Full Text Search
 

To Download GPBW52V04 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output GPBW52V04 - 1/2 Brick Bolero HV Series
* * * * * * * * * * * Industry standard pinout and footprint Highest efficiency in the industry: 92% at 52V, 4A; 91% at 52V, 2A No heat sink required (baseplate standard) Very low common-mode noise for a commercial DC/DC converter Two-stage input filter Constant switching frequency, 330 kHz Remote sense Single board SMT construction Low profile, 0.43" Optional low profile heat sink or baseplate for improved thermal performance Header with M3 metal inserts for mechanical connection to PCB
POWER PRODUCTS
GPBW52V04
Typical Characteristics
* * * * * * * * Output setpoint accuracy: 2% Load regulation: 0.25% Line regulation: 0.25% Regulation over line, load and temperature: 2% Low output ripple 50% output trim-down Supports IEEE 802.3af power over LAN 2250V isolation
Control Functions
* * Microprocessor controlled Primary-side enable, choice of logic
Protection Features
* * * * Over temperature protection Over voltage protection Over current protection Over/Under input voltage protection
Ordering Information
Standard Model Number GPBW52V04* * Options: M = 0.145" Pins ( .01") Input Voltage 48V Output Voltage 52V Max Current 4A Example Part Number: (All options)
R = Heat Sink-Ready G = Case Ground Pin
GPBW52V04 M R G 0 0 X
Part Number Options: Optional Pin Lengths E = 0.18" M = 0.145" (Std.) S = 0.12" Heat Sink-Ready Plate (Std.) Case Ground Pin (Std.) Heat Sink 001 = 0.25" 002 = 0.50" 003 = 1.00" 004 = 0.13"
Specifications subject to change without notice. 11.06
Bolero HV Heat Sink Part Numbers
Part Number 001 002 003 004 Height 0.25" 0.50" 1.00" 0.13"
Typical Thermal Performance Natural Convection Power Dissipation 5W 7W 11W TBD @ 300'/min. Forced Convection Thermal Resistance 5.8 C/W 3.2 C/W 2.0 C/W TBD
@ 60 C rise heat sink to ambient
(c)2006 Bel Fuse Inc.
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 1
POWER PRODUCTS
GPBW52V04
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output
Input Specifications
Parameter Operating Input Voltage Input Current Input Capacitance Input Hysteresis, Low Line 5 2 Min 36 Typical 48 Max 75 7 Units VDC A F VDC
VIN = 48VDC, TA@25 C, 300 LFM Airflow, VOUT = 52VDC, IOUT = Full load unless otherwise noted. COUT = 180F Al-Elec. Available output power depends on ambient temperature and good thermal management. (See application graphs for limits.)
Output Specifications
Parameter Setpoint Voltage Ripple, 180F Load Capacitance Voltage Ripple, 180F Load Capacitance Current Range Current Limit Inception Short Circuit Current1 Settling Time to 1%2 Turn-on Time to 98% Vnom Output Overshoot at Turn-on Trim Range, Lucent 1/2 Brick Trim Over Voltage Protection, Latching 50 115 0 100 120 6 1 40 None 105 Min 51.45 Typical 52.50 Max 53.55 30 80 4 Units VDC mV RMS mV P-P A %IOUT A mS mS %VOUT %VOUT %VOUT
1. During short circuit, converter will shut down and attempt to restart once per second. The average current during this condition will be very low and the device can be safely left in this condition continuously. 2. 50% load change only resulted in 1% output voltage step.
(c)2006 Bel Fuse Inc.
Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 2
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output
POWER PRODUCTS
GPBW52V04
Isolation Specifications
Parameter Isolation Test Voltage, Input/Output (Basic) Isolation Resistance Min 2250 10 Typical Max Units VDC M
Features
Parameter Over Temperature Protection, Thermal Sensor, Latching3 Input, Output Ripple Frequency, Fixed 3. PCB less than 130 C. 330 Min Typical Max 115 Units
C
kHz
General Specifications
Operating Temperature, Baseplate Storge Temperature Relative Humidity Vibration Material Flammability Weight MTBF Bellcore TR-332 -40 C to + 100 C -55 C + 125 C 10% to 95% RH, Non-condensing 2 to 9 Hz, 3mm disp., 9 to 200 Hz, 1g UL V-0 55 grams 1.6 million hours
Approvals and Standards
UL and c-UL Recognized Component, TUV, UL1950, CSA 22.2 No. 950, IEC/EN 60950** Pending. EMC Characteristics: Designed to meet emission and immunity requirements per EN55022, CISPR 22, Class B, and CISPR 24. ** An external fuse shall be used to comply with the requirements.
(c)2006 Bel Fuse Inc.
Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 3
POWER PRODUCTS
GPBW52V04
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output
Application Notes
CoolConverterTM
Bel Power's Proprietary CoolConverterTM * Patented single-stage power conversion architecture, control and magnetic design allow unprecedented power density and efficiency in an isolated power supply. * An advanced microcontroller reduces parts count while adding features, performance and flexibility in the design.
Protection and Control
Valid Input Voltage Range The converter measures the input voltage and will not allow operation outside of the input voltage specification. As shown by the graphs, hysteresis is added to both the high and low voltage to prevent the converter from turning on and off repeatedly when the voltage is held near either voltage extreme. At low line, this assures the maximum input current is not exceeded; at high line, this assures the semiconductor devices in the converter are not damaged by excessive voltage stress. ON/OFF Logic Option The ON/OFF control logic can be either Negative (standard) or Positive to enable the converter. For Negative logic, the ON/OFF pin is brought to below 1.0V with respect to the -INPUT pin to enable the converter. The pull-down must be able to sink 100A. For Positive logic, the ON/OFF pin is brought to greater than 4.0V with respect to the -INPUT pin and be limited to less than 10V. To request the Positive logic version, add the suffix (P) to the standard part number. The ON/OFF pin has a built-in pull-up resistor of approximately 100k to +5V. Output Over Voltage Protection The output voltage is constantly monitored by the microprocessor with a redundant secondary-side measurement circuit that both shuts down the duty cycle and triggers the microprocessor to shut down. If the output voltage exceeds the over voltage specification, the microprocessor will latch the converter off. To turn the converter on required either cycling the ON/OFF pin or power to the converter. This advanced feature prevents the converter from damaging the load if there is a converter failure or application error. If nonlatching is required, consult factory.
Output Voltage (V)
Over Voltage Hysteresis
6 5 4 3 2 1 0 76.5
Output Voltage (V)
77
77.5
78
78.5
79
79.5
80
80.5
Input Voltage (V)
Under Voltage Hysteresis
6 5 4 3 2 1 0 30
31
32
33
34
35
36
37
Input Voltage (V)
(c)2006 Bel Fuse Inc.
Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 4
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output
POWER PRODUCTS
GPBW52V04
CoolConverterTM
Protection and Control
Thermal Shutdown The printed circuit board temperature is measured using a semiconductor sensor. If the maximum rated temperature is exceeded, the converter is latched off. To re-enable the converter requires cycling the ON/OFF pin or power to the converter. If non-latching shutdown is required, consult factory. Control Options As the behavior of the circuit is determined by firmware in the microcontroller, specific requirements, such as: * non-latching thermal protection * custom valid input voltage range * controlled delay from initiating an ON/OFF signal for power sequencing can be accomplished with no change to hardware. The standard behavior was chosen based on system design experience, but customers may have their own requirements. Please contact Bel Power for any special needs. Remote Sense The output voltage is regulated at the point where the sense pins connect to the power output pins. Total sense compensation should not exceed 0.4V or 2% of Vout, whichever is greater. Trim-down Safety An external input fuse must always be used to meet these safety requirements. External Output Trimming RTRIM-DOWN = Trim-up
RTRIM-UP
=
{
Vo(100+%) 1.225%
_
(100+2%) %
}
k
52V Trim-up
10000
Trim Resistance (k)
1000
100
0
1
2
3
4
5
6
7
8
9
10
Increase in Output Voltage (%)
{
100_ 2 %
}
k
Trim-down
6
6
Trim Resistance (k)
1000
7
7
100
8
8
10
Trim To trim the output voltage higher, connect the required trim resistor from the Trim pin to the +Sense pin. To trim the output voltage lower, connect the required trim resistor from the Trim pin to the -Sense pin. See diagram above.
0 0 1 2 3 4 5 6 7 8 9 10
Decrease in Output Voltage (%)
(c)2006 Bel Fuse Inc.
Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 5
POWER PRODUCTS
GPBW52V04
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output
Efficiency Data Efficiency
94 92
Power Dissipation
36V Vin 48V Vin 75V Vin
Efficiency (%)
90 88 86 84 82 80 0 1 2 3 4
40V Vin 48V Vin 60V Vin
Load Current (A)
Start Up
[
T
T
Voltage Ripple Ripple
]
150
100
Vout (mV)
50
1
0
Vout
-50
2
-100
-150
Ch1 20.0V
BW
Ch2
5.00 V
BW
M 10.0ms A
Ch2
1.80V
0
5
10
Time (S)
15
20
25
1. VOUT 20V/div 10mS/div 2. VOUT 5V/div 10mS/div
1. VOUT 50mV/div 2S/div 10F ext cap 2MHz BW
Line/Load Regulation
53.700 53.600
Output Voltage (V)
53.500 53.400 53.300 53.200 53.100 53.000 52.900 52.800 0 2 4
36V Vin 48V Vin 75V Vin
Output Current (A)
(c)2006 Bel Fuse Inc.
Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 6
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output
POWER PRODUCTS
GPBW52V04
Transient Response
Transient Response
50% to 75% Load Transients at VIN = 48V@TA = 25C
75% to 50% Load Transients at VIN = 48V@TA = 25C
(c)2006 Bel Fuse Inc.
Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 * Tel 508-870-9775 * Fax 508-870-9796 * www.belpower.com page 7
BOLERO HV DC/DC CONVERTERS
48V Input - 52VDC - 4A Output Mechanical
GPBW52V04
0.5 0.01 MOUNTING INSERT CONNECTED TO CASE PIN 2 2.000 PIN 4, PIN 3, 2.40 PIN 2, PIN 1, .700 .300 0 .20 0 .19 1.700 1.300
POWER PRODUCTS
GPBW52V04
SIDE VIEW
1.700 PIN 5 1.300 PIN 6 1.000 PIN 7 .700 PIN 8 .300 PIN 9 0 REF. MOUNTING INSERT M3 X 0.5, 4 PLACES 2.28 1.900 BOTTOM VIEW
Pin Configuration - Bottom View
Pin 1 2 3 4 5 6 7 8 9 Function - Input Case Ground Pin On/Off + Input + Output + Sense Trim - Sense - Output Pin Dia. (In.) 0.040 0.040 0.040 0.040 0.080 0.040 0.040 0.040 0.080
Notes: 1. Mechanical tolerances x.xxx in. = 0.005 in. x.xx in = 0.01 in. 2. Pin material: Brass with tin/lead plating over nickel 3. Workmanship: Meets or exceeds IPC-A-610B Class II 4. Min. screw length for heat sink attachment = 4.5mm + heat sink flange + locking hardware
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. These parts are not however compatible with the higher temperatures associated with lead free solder processes and must be soldered using a reflow profile with a peak temperature of no more than 240C.
(c)2006 Bel Fuse Inc. Specifications subject to change without notice. 11.06
CORPORATE
Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com
FAR EAST
Bel Fuse Ltd. 8F / 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com
EUROPE
Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com
page 8


▲Up To Search▲   

 
Price & Availability of GPBW52V04

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X